160psi High Pressure Diaphragm Water Pump for Car Wash, Agriculture sprayer, Marine
7.0LPM/1.8GPM 80PSI
APPLICATIONS
- Agriculture/Yacht / RV/Caravan pressurized water system
- Sprayer fixture (Vehicle-mounted sprayer, electric sprayer)
- Cleaning machine, Humidifier, Water purification, Medical apparatus
- Any other pressurization system
Materials of Construction
Housings: |
Polypropylene |
Valves: |
Viton |
Diaphragm: |
Santoprene |
Fasteners: |
Stainless Steel |
Motor Shell: |
Coated Steel |
PUMP
Motor Type: |
12 VDC permanent magnet, totally enclosed, non-ventilated |
Amps |
9.0A Max |
Certification |
CE, ISO9001:2008, RoHS |
Flow Rate |
5.5LPM/1.5GPM |
Pressure |
100psi/6.9bar |
Port dimension |
3/8" FNPT |
Diaphragm |
Santoprene |
Valve |
Viton or EPDM |
Duty Cycle |
Intermittent |
How a Diaphragm Pump Works
The pump is driven by an AC or DC motor in front of the motor is a valve assembly containing two to five valve pump chambers. Each valve chamber has a diaphragm behind it in the lower pump housing. As the motor shaft turns, an internal cam positioned behind the diaphragms causes the diaphragms to be pushed forward, then back in a continuous sequence creating a suction. As this suction builds, fluid is pulled through the inlet, through the various valve chamber check valves to the outlet. The volume of flow is determined by several factors including: the number and size of the pump chambers, cam offset, operating pressure, fluid viscosity
STANDARD PUMP CONFIGURATIONS
Model |
Switch |
GPM/LPM |
PSI/BAR |
Max Draw(A) |
Valves |
Diaphragm |
Ports |
Voltage |
Wire Connections |
KDP-3180A |
Demand |
1.5/5.5 |
80/5.5 |
7 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-3180B |
Demand |
1.5/5.5 |
80/5.5 |
4 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-31100A |
Demand |
1.5/5.5 |
100/6.9 |
9 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-31100B |
Demand |
1.5/5.5 |
100/6.9 |
4.5 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-31120A |
Demand |
1.5/5.5 |
120/8.3 |
10 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-31120B |
Demand |
1.5/5.5 |
120/8.3 |
5 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-31160A |
Demand |
1.5/5.5 |
160/11.0 |
12 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-31160B |
Demand |
1.5/5.5 |
160/11.0 |
6 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-3180C |
Demand |
1.8/7.0 |
80/5.5 |
9 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-3180D |
Demand |
1.8/7.0 |
80/5.5 |
4.5 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-31100C |
Demand |
1.8/7.0 |
100/6.9 |
10 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-31100D |
Demand |
1.8/7.0 |
100/6.9 |
5 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-31120C |
Demand |
1.8/7.0 |
120/8.3 |
12 |
Viton |
Santoprene |
3/8"-18 FNPT |
12V |
2-Pin/Leads |
KDP-31120D |
Demand |
1.8/7.0 |
120/8.3 |
6 |
Viton |
Santoprene |
3/8"-18 FNPT |
24V |
2-Pin/Leads |
KDP-31120E |
Demand |
1.5/5.5 |
120/8.3 |
0.8 |
Viton |
Santoprene |
3/8"-18 FNPT |
110V |
Leads |
KDP-31120F |
Demand |
1.5/5.5 |
120/8.3 |
0.5 |
Viton |
Santoprene |
3/8"-18 FNPT |
220V |
Leads |
KDP-31160E |
Demand |
1.5/5.5 |
160/11.0 |
1.1 |
Viton |
Santoprene |
3/8"-18 FNPT |
110V |
Leads |
KDP-31160E |
Demand |
1.5/5.5 |
160/11.0 |
0.6 |
Viton |
Santoprene |
3/8"-18 FNPT |
220V |
Leads |
PUMP PERFORMANCE
|
1.8 GPM |
|
1.5 GPM |
PSI |
BAR |
GPM |
LPM |
PSI |
BAR |
GPM |
LPM |
OPEN |
0 |
1.77 |
6.7 |
OPEN |
0 |
1.43 |
5.4 |
10 |
0.69 |
1.66 |
6.3 |
10 |
0.69 |
1.36 |
5.15 |
20 |
1.38 |
1.56 |
5.9 |
20 |
1.38 |
1.27 |
4.8 |
30 |
2.07 |
1.48 |
5.6 |
30 |
2.07 |
1.22 |
4.62 |
40 |
2.76 |
1.4 |
5.3 |
40 |
2.76 |
1.16 |
4.4 |
50 |
3.45 |
1.29 |
4.9 |
50 |
3.45 |
1.11 |
4.2 |
60 |
4.14 |
1.22 |
4.6 |
60 |
4.14 |
1.06 |
4 |
70 |
4.83 |
1.19 |
4.5 |
70 |
4.83 |
1.03 |
3.9 |
80 |
5.52 |
1.16 |
4.4 |
80 |
5.52 |
1 |
3.8 |
90 |
6.21 |
1.14 |
4.3 |
90 |
6.21 |
0.98 |
3.7 |
100 |
6.9 |
1.11 |
4.2 |
100 |
6.9 |
0.95 |
3.6 |
110 |
7.59 |
1.08 |
4.1 |
110 |
7.59 |
0.9 |
3.4 |
120 |
OFF |
0 |
0 |
120 |
8.28 |
0.87 |
3.3 |
|
130 |
8.97 |
0.85 |
3.2 |
140 |
9.66 |
0.82 |
3.1 |
150 |
10.34 |
0.79 |
3 |
160 |
11.03 |
OFF |
0 |
DIMENSIONS DRWING
EXPLODED VIEW
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Complete Pumphead Assembly |
Switch Assembly |
Check Valve Assembly |
Upper Housing |
Bypass / Non-Bypass Valve Assembly |
Diaphragm Assembly |
Drive Assembly |
Motors |
CHEMICAL RESISTANCE
Chemical Resistance labels |
Max Temperature Resistance Code |
A —— Excellent
B —— Good
C —— Ordinary
× —— Unacceptable
- —— Unusable
|
1 —— 20℃(68F)
2 —— 40℃(104F)
3 —— 60℃(140F)
4 —— 80℃(176F)
5 —— 100℃(212F)
6 —— 120℃(248F)
|
CHEMICAL |
MATERIAL |
PP |
PTFE |
FKM |
NBR |
EPDM |
95 Ceramic |
Sulfuric Acid |
0-10% |
A4 |
A6 |
A6 |
B2 |
A4 |
A5 |
10-75% |
A3 |
A6 |
A4 |
X |
A3 |
A5 |
75-100% |
B2 |
A4 |
A4 |
- |
B2 |
A5 |
Nitric Acid |
10% |
A3 |
A5 |
A5 |
X |
A2 |
A5 |
30% |
A2 |
A6 |
A6 |
X |
A2 |
A5 |
50% |
B2 |
A3 |
A1 |
X |
X |
A5 |
Hydrochloric Acid |
0-25% |
A4 |
A6 |
A3 |
B1 |
C3 |
A5 |
25-40% |
A4 |
A6 |
A2 |
X |
C2 |
A5 |
Hydrofluoric Acid |
10% |
B2 |
A6 |
A3 |
X |
A3 |
- |
30% |
C2 |
A6 |
A4 |
- |
B3 |
- |
60% |
X |
A6 |
A4 |
- |
C2 |
- |
Acetic Acid |
20% |
A2 |
A6 |
B1 |
B2 |
A2 |
A5 |
80% |
B1 |
A6 |
X |
- |
- |
A5 |
Sodium Hydroxide |
20% |
A3 |
A6 |
B1 |
B2 |
A3 |
- |
50% |
A3 |
A6 |
X |
B1 |
A4 |
- |
Bromine Water |
C1 |
A3 |
A2 |
- |
X |
A1 |
Ethyl Alcohol |
A2 |
A3 |
A3 |
X |
B3 |
A3 |
Acetone |
A2 |
A6 |
X |
- |
B2 |
A3 |
Freon 12 |
X |
A6 |
A1 |
X |
B1 |
A4 |
Aluminum Chloride |
A4 |
A6 |
A5 |
B4 |
A4 |
A4 |
Ammonia Liquid |
A1 |
A6 |
C1 |
B4 |
B3 |
A3 |
Aqua Regia |
C2 |
A5 |
B2 |
- |
C2 |
A4 |
Formaldehyde |
A4 |
A6 |
A4 |
X |
A4 |
A4 |
Gasoline |
X |
A6 |
B3 |
B3 |
X |
A4 |
Kerosene |
A1 |
A6 |
A1 |
B1 |
X |
A4 |
Methyl Alcohol |
A3 |
A6 |
B2 |
B4 |
A3 |
A5 |
Toluene |
C1 |
A4 |
B1 |
- |
X |
A5 |
Trichloroethylene |
C1 |
A6 |
A1 |
- |
X |
A4 |
Xylene |
X |
A6 |
B1 |
- |
X |
A5 |
Nitric Acid Anhydrous |
C1 |
A3 |
A1 |
- |
X |
A5 |
Oleum |
X |
A6 |
A4 |
- |
X |
A5 |
Potassium Hydroxide |
A4 |
A6 |
B1 |
C2 |
A5 |
- |
USAGE SCOPE
Widely used in general industrial equipment, medical equipment, chemical equipment, agricultural (lawns and gardens), tourist vehicles, special vehicles, ships, beverage, vehicle cleaning, carpet cleaning, floor cleaning, water purification and water treatment equipment.
1. Production of agricultural use electric sprayer, pressure sprayer can also be hand modified electric sprayer (pressure sprayer in hand directly on the micro-pumps, adding a battery or hand lamp can be).
2. Solve vehicles, ships, yachts, boats, etc. in use diet, wash, shower, toilet, wash water.
3. Food and beverage processing and handling equipment, to achieve the transfer of liquid food, distribution, filling and so on.
4. Domestic water supply. For example, water-saving toilet, water-saving toilet, electric toilet, pressurized water system.
5. Solar energy industry.
6. Water purification industry. For example, purification equipment, water treatment equipment, drinking fountains, water machines. For towel disposal, drinking fountains, Coke machines, juice machines, dishwashers, disinfection machines, solar bonsai, car washing and other manufacturers supporting the glass.
7. Other liquid transfer needs, as well as measurement of spray equipment and systems. For example, garbage trucks, water truck, carpet cleaning equipment, floor cleaning equipment, cleaning equipment, vehicles, road construction equipment, medical equipment, chemical equipment, chemical equipment, disinfection equipment, cooling systems, pressurization systems.